WindGenType3aIEC
cim:WindGenType3aIEC
IEC type 3A generator set model. Reference: IEC 61400-27-1:2015, 5.6.3.2.
Inherits from: WindGenType3IEC
Validations
tic
Current PI controller integration time constant (TIc) (>= 0). It is a type-dependent parameter.
- Minimum Value: 0.0
- Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)