WindContPType4bIEC
cim:WindContPType4bIEC
P control model type 4B. Reference: IEC 61400-27-1:2015, 5.6.5.6.
Inherits from: IdentifiedObject
Validations
tpaero
Time constant in aerodynamic power response (Tpaero) (>= 0). It is a type-dependent parameter.
- Minimum Value: 0.0
- Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)
tpordp4b
Time constant in power order lag (Tpordp4B) (>= 0). It is a type-dependent parameter.
- Minimum Value: 0.0
- Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)
tufiltp4b
Voltage measurement filter time constant (Tufiltp4B) (>= 0). It is a type-dependent parameter.
- Minimum Value: 0.0
- Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)