Skip to content

GovSteamFV2

cim:GovSteamFV2

Steam turbine governor with reheat time constants and modelling of the effects of fast valve closing to reduce mechanical power.

Inherits from: TurbineGovernorDynamics

Validations

mwbase

Alternate base used instead of machine base in equipment model if necessary (MWbase) (> 0). Unit = MW.

  • Minimum Value: 0.0
  • Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)

t1

Governor time constant (T1) (>= 0).

  • Minimum Value: 0.0
  • Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)

t3

Reheater time constant (T3) (>= 0).

  • Minimum Value: 0.0
  • Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)

ta

Time after initial time for valve to close (Ta) (>= 0).

  • Minimum Value: 0.0
  • Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)

tb

Time after initial time for valve to begin opening (Tb) (>= 0).

  • Minimum Value: 0.0
  • Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)

tc

Time after initial time for valve to become fully open (Tc) (>= 0).

  • Minimum Value: 0.0
  • Source: ENTSOE Application Profiles Library v1.1.0 (61970-302_Dynamics-AP-Con-Complex-SHACL_v3-0-0.ttl)

tt

Time constant with which power falls off after intercept valve closure (Tt) (>= 0).

  • Minimum Value: 0.0